Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Iran Endod J ; 19(2): 75-84, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577004

RESUMO

Introduction: Foraminal Enlargement (FE) is a cleaning performed in the apical-most region of the tooth, in order to optimize root disinfection. This systematic review evaluated the influence of FE during root canal treatment on bacterial reduction and repair of the periapical lesion. Materials and Methods: Searches in PubMed/MEDLINE, Scopus, Cochrane Library, Web of Science, Embase, Scielo, Lilacs and OpenGrey were performed until January-2024. Ex vivo and in vivo studies evaluating the effects of FE in the bacterial reduction and repair of the periapical lesion were included, respectively, followed by risk of bias assessment (modified version of Joanna Briggs Institute's for ex vivo studies and Systematic Review Centre for Laboratory animal Experimentation's risk of bias tools for in vivo studies). The meta-analysis was not feasible and a qualitative summary for each outcome was provided. Results: Of 950 studies, 2 in vivo studies were eligible, using animal models with infected teeth. Of these two, periapical repair was evaluated with hematoxylin-eosin stain, and FE improved periapical healing. Regarding ex vivo studies, 3 were eligible, using extracted human teeth. The inoculations in ex vivo models were performed with Enterococcus (E.) faecalis, and FE reduced E. faecalis in the ex vivo models. Conclusions: Foraminal enlargement seems to increase bacterial reduction within the root canal, and provide major periapical tissue repair on the histological analysis in animal studies. However, caution is necessary when translating these results to the clinical environment.

2.
Eur J Dent ; 17(2): 472-477, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36195211

RESUMO

OBJECTIVE: The aim of this study was to compare the cyclic fatigue of heat-treated and non-treated instruments. MATERIALS AND METHODS: Twenty instruments with and without heat treatment from Bassi Logic were evaluated (n = 10). All instruments were subjected to dynamic cyclic fatigue through continuous rotations inside a stainless-steel tube (1.4-mm diameter, 9-mm curvature with 6-mm radius, and 90° angle) using a custom-made device, which performed 1 axial oscillation every 2 seconds with an amplitude of 3 mm, powered by a torque-controlled motor (Silver Reciproc, VDW, Germany), with speed adjusting to 950 rpm and torque to 4 N, according to manufacturer's guidance. The groups were compared using the Mann-Whitney test. RESULT: The fracture time of the heat-treated instruments (97.20 ± 39.94 second and non-treated instruments (14.30 ± 6.78 seconds had statistical differences [p < 0.05]). Heat-treated instruments were 6.8 times more resistant to fatigue than non-treated instruments (p < 0.05). CONCLUSION: Heat treatment provides increased fatigue resistance of NiTi alloy with the same design.

3.
Belo Horizonte; s.n; 2023. 64 p. ilus, graf, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1509346

RESUMO

A introdução da liga NiTi na endodontia proporcionou a fabricação de instrumentos com excelentes propriedades mecânicas, e uma das principais características é a possibilidade de alteração das temperaturas de transformação da liga, o qual pode possibilitar a presença de martensita em temperatura ambiente e consequentemente um efeito memória de forma. Entretanto, alguns dos sistemas comercializados atualmente possuem pouca ou nenhuma informação científica relatando suas propriedades mecânicas, características de design e métodos de fabricação. O objetivo deste trabalho foi comparar características geométricas, metalúrgicas e propriedades mecânicas (resistência à torção e flexão) de instrumentos Reciproc Blue (VDW, Munique, Alemanha), e quatro sistemas reciprocantes réplicas. Um total de 39 instrumentos de cada um dos sistemas reciprocantes, Reciproc Blue (RB), Prodesign R (PDR), V File (VF), V+ File (V+) e Univy One (UO) foram utilizados na pesquisa. O programa de Image J foi utilizado para mensuração dos diâmetros a cada milímetro da parte ativa e da área da seção transversal a 3 mm da ponta dos instrumentos. Imagens de MEV da parte ativa foram realizados para avaliar o acabamento superficial dos instrumentos. A composição atômica, fases presentes e temperaturas de transformação foram verificadas através de EDS, DRX e DSC, respectivamente. A flexibilidade foi aferida através de ensaios de dobramento até 45º conforme a especificação ISO 3630-1, e os ensaios de resistência à torção foram realizados de acordo com a especificação Nº28 ANSI/ADA. Todos os instrumentos apresentaram uma quantidade aproximadamente equiatômica de níquel e titânio. A análise qualitativa das fases cristalinas realizada através de ensaios de DRX, demonstrou a predominância de Fase R em todos os grupos, com exceção do grupo UO que apresenta uma mistura de fase R e martensita B19'. Na avaliação da área da seção, o instrumento RB obteve valores intermediários, os instrumentos PDR e V+ possuem menores valores e os instrumentos VF e UO possuem maiores valores. Observou-se grande impacto da geometria sobre as propriedades mecânicas, sendo que aqueles sistemas que apresentavam menor área que RB (PDR, V+) mostraram-se mais flexíveis e menos resistentes à torção (p<0.05), e o instrumento VF que teve maior área apresentou, como esperado, menos flexibilidade (p<0.05) e resistência torcional semelhante (p>0.05). A única exceção se deu com o sistema UO, que embora apresentasse uma maior área de seção, mostrou-se mais flexível e menos resistente à torção, provavelmente por influência da maior quantidade de martensita presente à temperatura ambiente. Nenhum dos instrumentos réplicas avaliados apresentaram características e comportamento mecânico iguais ao sistema padrão RB. Sugere-se que mais estudos devem ser realizados para a comparação do comportamento clínico destes instrumentos.


The introduction of NiTi alloy in endodontics has allowed the manufacturing of instruments with excellent mechanical properties, and one of the main characteristics is the ability to change alloy's transformation temperature, which can enable the presence of martensite at room temperature and consequently favor a shape memory effect. However, some of the currently marketed systems have limited or no scientific information regarding their mechanical properties, design characteristics, and manufacturing methods. The aim of this study was to compare the geometric characteristics, metallurgical aspects, and mechanical properties (torsional and flexural strength) of Reciproc Blue instruments (VDW, Munich, Germany) with four replica-like reciprocating systems. A total amount of 39 instruments from each reciprocating system, namely Reciproc Blue (RB), Prodesign R (PDR), V File (VF), V+ File (V+), and Univy One (UO), were used in the study. The Image J program was used to measure the diameters at every millimeter along the instruments active portion and the cross-sectional area at 3 mm from the instrument tip. SEM images of the active portion were obtained to evaluate the surface finishing of the instruments. Atomic composition, phases present, and transformation temperatures were determined through EDS, XRD, and DSC analyses, respectively. Flexibility was assessed by bending tests up to 45° according to ISO 3630-1 specifications, and torsional strength tests were performed according with ANSI/ADA Specification No. 28. All instruments exhibited an approximately equiatomic composition of nickel and titanium. Qualitative analysis of the crystalline phases using XRD tests demonstrated the predominance of the R-phase in all groups, except for the UO group, which exhibited a mixture of Rphase and B19' martensite. In terms of diameter and cross-sectional area evaluation, the RB instrument obtained intermediate values, while the PDR and V+ instruments had smaller values, and the VF and UO instruments had larger values. A significant impact of geometry on mechanical properties was observed, with systems exhibiting a smaller area than RB (PDR, V+) being more flexible and less torsion-resistant (p<0.05), and the VF instrument with a larger area showed, as expected, less flexibility (p<0.05) and similar torsional resistance (p>0.05). The only exception was the UO system, which, despite having a larger geometric configuration, exhibited greater flexibility and less torsional resistance, likely due to the higher amount of martensite present at room temperature. None of the replica-like instruments evaluated showed identical characteristics and mechanical behavior to the standard RB system. Further studies are suggested to compare the clinical performance of these instruments.


Assuntos
Varredura Diferencial de Calorimetria , Endodontia , Torção Mecânica , Ligas de Memória da Forma , Testes Mecânicos
4.
Braz. dent. sci ; 26(4): 1-11, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1523867

RESUMO

Foraminal enlargement has been recommended to optimize the disinfection of infected root canals, although some authors still claim that the foramen should be kept in its original shape and position. This study aimed to evaluate morphological alterations of apical foramen after foraminal enlargement through a systematic review. An electronic search was conducted until April 2022. Ex vivo studies evaluating influence of foraminal enlargement in the morphologic changes of apical foramen were included. Studies without a control group or available full text were excluded. Foraminal deformation and area increase were considered as primary outcomes. Risk-of-bias assessment was performed according to a modified Joanna Briggs Institute's Checklist. From 702 studies retrieved, five were eligible. Most studies used single-rooted teeth, and rotary systems for instrumentation ranging from ­ 2 mm to + 1 mm to the apex. All studies found increased major foramen deformation after foraminal enlargement. Among four studies that evaluated foraminal area, all found increased area after foraminal enlargement. Insufficient data for touched/untouched walls by instruments and dentinal microcrack formation was observed. A low risk of bias was found. Foraminal enlargement during root canal preparation seems to increase deformation and major apical foramen area. Future investigations with standardized methodologies are encouraged (AU)


A ampliação foraminal tem sido recomendada para otimizar a desinfecção de canais radiculares infectados, embora alguns autores ainda afirmem que o forame deve ser mantido em sua forma e posição originais. Este estudo teve como objetivo avaliar alterações morfológicas do forame apical após ampliação foraminal por meio de uma revisão sistemática. Uma busca eletrônica foi realizada até abril de 2022. Foram incluídos estudos ex vivo que avaliaram a influência da ampliação foraminal nas alterações morfológicas do forame apical. Foram excluídos estudos sem grupo controle ou com texto completo indisponível. A deformação foraminal e o aumento da área foram considerados desfechos primários. A avaliação do risco de viés foi realizada de acordo com uma lista de verificação modificada do Instituto Joanna Briggs. Dos 702 registros recuperados, cinco foram elegíveis. A maioria dos estudos utilizou dentes unirradiculares e sistemas rotatórios para instrumentação, com comprimento de trabalho variando de ­ 2 mm a + 1 mm até o ápice. Todos os estudos encontraram aumento da deformação do forame maior após ampliação foraminal. Dos quatro estudos que avaliaram a área foraminal, todos encontraram aumento de área após alargamento foraminal. Foram observados dados insuficientes para paredes tocadas/intocadas pelos instrumentos e formação de microfissuras dentinárias. Um baixo risco de viés foi encontrado. A ampliação foraminal durante o preparo do canal radicular parece aumentar a deformação e a área do forame apical. Futuras investigações com metodologias padronizadas são incentivadas (AU)


Assuntos
Tratamento do Canal Radicular , Preparo de Canal Radicular , Ápice Dentário , Endodontia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...